Lucheng HuirRe Electronics

Location:Home > Products > Thermocouple Wires

Products

  • T-Type

T-Type

Key words:T-Type
Classification:Thermocouple Wires
Summary:Copper-copper-nickel thermocouple, also known as T-type thermocouple, has a detection range of - 200-400 C. This thermocouple is suitable for use in oxidation and neutral atmosphere. It has the advantages of high sensitivity...
Online order
Details Photo Gallery
无标题文档

Thermocouple alloys (wires):

Nickel-Chromium-Nickel-Silicon Thermocouple Wire (Type K)
Nickel-Chromium-Copper-Nickel Thermocouple Wire (Type E)
Copper-Copper nickel (constantan) thermocouple wire (T type)
Fe-Cu-Ni (CONTANT) THERMOCOUPLE WIRE (Type J)
Nickel Chromium Silicon-Nickel Silicon Thermocouple Wire (Type N)


Main properties and applications:
These thermocouples are characterized by good linearity, sensitivity, stability, uniformity and oxidation resistance. They are widely used in metallurgical, chemical, electric power, instrumentation, national defense and other industrial sectors.


Measurement range and allowable deviation of thermocouple

Name Model

Model

Grade

Use temperature range(°C)

Allowable deviation

     Nickel-Chromium-Nickel-Silicon

K


      -40~1100
      -40~1300

     ±1.1°C或±0.4%t
     ±2.2°C或±0.75%t

     Nickel-Chromium-Copper-Nickel

E


      -40~800
      -40~900

     ±1.0°C或±0.4%t
     ±1.7°C或±0.75%t

     Iron-copper-nickel

J


      -40~750
      -40~750

     ±1.5°C或±0.4%t
     ±2.5°C或±0.75%t

     Copper-Kang Copper

T


      -200~400

     ±0.5°C或±0.4%t
     ±1°C或±0.75%t

     Nickel Chromium Silicon-Nickel Silicon

N


      -40~1100
      -40~1300

     ±1.1°C或±0.4%t
     ±2.2°C或±0.75%t

Type T